10440 | 8550-021 60 Meg ESDI Adapter Error. | |
10441 | 8550-021 60 Meg ESDI Adapter Error. | |
10442 | 8550-021 60 Meg ESDI Adapter Error. | |
10443 | 8550-021 60 Meg ESDI Adapter Error. | |
10444 | 8550-021 60 Meg ESDI Adapter Error. | |
10445 | 8550-021 60 Meg ESDI Adapter Error. | |
10446 | 8550-021 60 Meg ESDI Adapter Error. | |
10447 | 8550-021 60 Meg ESDI Adapter Error. | |
10450 | DIAGS Error - Replace drive (read write test failed) | |
10451 | DIAGS Error - Replace drive (read verify test failed) | |
10452 | DIAGS Error - Replace drive (seek test failed) | |
10453 | DIAGS Error - Replace drive (wrong drive type indicated) | |
10454 | DIAGS Error - Controller (controller test failed sector buffer test) | |
10455 | DIAGS Error - Controller (controller failure, invalid failure) | |
10456 | DIAGS Error - Controller ( | DIAG command failure) |
10457 | DIAGS Error - Repl. drive (integrated controller test failure) | |
10458 | DIAGS Error - Repl. drive (integrated controller test failure) | |
10458 | DIAGS Error - If 8570-121 or 8570-A21 see ECA020 | |
10459 | DIAGS Error - Replace drive ( | DIAG command failure) |
10460 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10461 | DIAGS Error - Drive fromat error | |
10462 | DIAGS Error - Controller (head select error) | |
10463 | DIAGS Error - Drive (read/write sector error) | |
10464 | DIAGS Error - Drive (primary map unreadable) | |
10465 | DIAGS Error - Controller (ECC 8 bit error) | |
10466 | DIAGS Error - Controller (ECC 9 bit error) | |
10467 | DIAGS Error - Drive (soft seek error) | |
10468 | DIAGS Error - Drive (hard seek error) | |
10469 | DIAGS Error - Drive (drive soft error count execeeded) | |
10470 | DIAGS Error - Controller (attachment | DIAG error) |
10471 | DIAGS Error - Controller (wrap mode interface error) | |
10472 | DIAGS Error - Controller (wrap mode drive selected error) | |
10473 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10474 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10475 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10476 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10477 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10478 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10479 | DIAGS Error - Unknown. Repl. drive, then controller, then system board | |
10480 | POST Error - Replace disk "C" (seek failure) | |
10480 | DIAGS Error - Controller (com/data-attn bad) | |
10481 | POST Error - Replace disk "D" (seek failure) | |
10481 | DIAGS Error - Controller (xfr req-ready bad) | |
10482 | POST Error - Replace controller (failed controller test) | |
10482 | DIAGS Error - Controller (drvsell-xfr ack bad) | |
10483 | POST Error - Replace controller (failed reset) | |
10483 | POST Error - If 8570-121 or 8570-A21 see ECA020 | |
10483 | DIAGS Error - Controller (drvse10-config/stat bad) | |
10484 | DIAGS Error - Controller (hdse13-selected bad) | |
10485 | DIAGS Error - Controller (hdse12-selected bad) | |
10486 | DIAGS Error - Controller (hdse11-selected bad) | |
10487 | DIAGS Error - Controller (hdse10-selected bad) | |
10488 | DIAGS Error - Controller (rg - cmd cmplt 2) | |
10489 | DIAGS Error - Controller (wg - cmd cmplt 1) | |
10490 | POST Error - Replace disk "C" (read failure) | |
10490 | DIAGS Error - Controller (drive connected no test done) | |
10491 | POST Error - Replace disk "D" (read failure) | |
10499 | DIAGS Error - Controller Failure |