104XX ESDI DRIVES AND ADAPTERS ERRORS

10440 8550-021 60 Meg ESDI Adapter Error.
10441 8550-021 60 Meg ESDI Adapter Error.
10442 8550-021 60 Meg ESDI Adapter Error.
10443 8550-021 60 Meg ESDI Adapter Error.
10444 8550-021 60 Meg ESDI Adapter Error.
10445 8550-021 60 Meg ESDI Adapter Error.
10446 8550-021 60 Meg ESDI Adapter Error.
10447 8550-021 60 Meg ESDI Adapter Error.
10450 DIAGS Error - Replace drive (read write test failed)
10451 DIAGS Error - Replace drive (read verify test failed)
10452 DIAGS Error - Replace drive (seek test failed)
10453 DIAGS Error - Replace drive (wrong drive type indicated)
10454 DIAGS Error - Controller (controller test failed sector buffer test)
10455 DIAGS Error - Controller (controller failure, invalid failure)
10456 DIAGS Error - Controller (DIAG command failure)
10457 DIAGS Error - Repl. drive (integrated controller test failure)
10458 DIAGS Error - Repl. drive (integrated controller test failure)
10458 DIAGS Error - If 8570-121 or 8570-A21 see ECA020
10459 DIAGS Error - Replace drive (DIAG command failure)
10460 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10461 DIAGS Error - Drive fromat error
10462 DIAGS Error - Controller (head select error)
10463 DIAGS Error - Drive (read/write sector error)
10464 DIAGS Error - Drive (primary map unreadable)
10465 DIAGS Error - Controller (ECC 8 bit error)
10466 DIAGS Error - Controller (ECC 9 bit error)
10467 DIAGS Error - Drive (soft seek error)
10468 DIAGS Error - Drive (hard seek error)
10469 DIAGS Error - Drive (drive soft error count execeeded)
10470 DIAGS Error - Controller (attachment DIAG error)
10471 DIAGS Error - Controller (wrap mode interface error)
10472 DIAGS Error - Controller (wrap mode drive selected error)
10473 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10474 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10475 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10476 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10477 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10478 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10479 DIAGS Error - Unknown. Repl. drive, then controller, then system board
10480 POST Error - Replace disk "C" (seek failure)
10480 DIAGS Error - Controller (com/data-attn bad)
10481 POST Error - Replace disk "D" (seek failure)
10481 DIAGS Error - Controller (xfr req-ready bad)
10482 POST Error - Replace controller (failed controller test)
10482 DIAGS Error - Controller (drvsell-xfr ack bad)
10483 POST Error - Replace controller (failed reset)
10483 POST Error - If 8570-121 or 8570-A21 see ECA020
10483 DIAGS Error - Controller (drvse10-config/stat bad)
10484 DIAGS Error - Controller (hdse13-selected bad)
10485 DIAGS Error - Controller (hdse12-selected bad)
10486 DIAGS Error - Controller (hdse11-selected bad)
10487 DIAGS Error - Controller (hdse10-selected bad)
10488 DIAGS Error - Controller (rg - cmd cmplt 2)
10489 DIAGS Error - Controller (wg - cmd cmplt 1)
10490 POST Error - Replace disk "C" (read failure)
10490 DIAGS Error - Controller (drive connected no test done)
10491 POST Error - Replace disk "D" (read failure)
10499 DIAGS Error - Controller Failure

Return To The PC And PS2 Error Codes Menu

Return To The COMPUTERCRAFT Main Menu