PC 91XX Error Codes

3363 OPTICAL DISK DRIVE ERRORS

9101 OPTICAL DISK POST ERROR - Drive #1 failed - Reseat Cables and Adapter
9102 OPTICAL DISK POST ERROR - Drive #1 failed - Reinsert Cartridge
9102 - Reseat Adapter
9103 OPTICAL DISK POST ERROR - Drive #1 failed - Reseat Cables and Adapter
9104 OPTICAL DISK POST ERROR - Drive #2 failed - Reseat Cables and Adapter
9105 OPTICAL DISK POST ERROR - Drive #2 failed - Reinsert cartridge
9105 - Reseat cables and Adapter
9106 OPTICAL DISK POST ERROR - Drive #2 failed - Reseat cables and Adapter
9107 OPTICAL DISK POST ERROR - Adapter hung on BUSY - Reseat Cables and Adapter
9110 OPTICAL DISK DIAGS ERROR - Data not recorded - Check Adapter, Drive, Cable
9111 OPTICAL DISK DIAGS ERROR - Data not readable - Check Adapter, Drive, Cable
9112 OPTICAL DISK DIAGS ERROR - Sector demarked - Check Adapter, Drive, Cable
9113 OPTICAL DISK DIAGS ERROR - Controller Error - Check Adapter, Drive, Cable
9113 - Check switch settings
9113 on Adapter DS302
9113 (8088 vs 80286)
9114 OPTICAL DISK DIAGS ERROR - Sector Read/Write Error - Check Drive, Adapter, or Cable
9115 OPTICAL DISK DIAGS ERROR - Scramble Buffer Error - Check Drive, Adapter
9115 - Check Cable
9116 OPTICAL DISK DIAGS ERROR - Data Buffer Error - Check Drive, Adapter
9116 - Check Cable
9117 OPTICAL DISK DIAGS ERROR - Drive RAM/ROM Error - Check Drive, Adapter
9117 - Check Cable
9118 OPTICAL DISK DIAGS ERROR - Invalid Command - Check Drive, Adapter, Cable
9119 OPTICAL DISK DIAGS ERROR - Track Jump Error - Check Drive, Adapter, Cable
9120 OPTICAL DISK DIAGS ERROR - Laser Error - Check Drive, Adapter, or Cable
9121 OPTICAL DISK DIAGS ERROR - Focus Error - Check Cartridge, Drive, Adapter, or Cable
9122 OPTICAL DISK DIAGS ERROR - Motor Sync Error - Cartridge upside down
9122 - Check Drive, Adapter, Cable
9123 OPTICAL DISK DIAGS ERROR - Write Fault - Check Drive, Adapter, or Cable
9124 OPTICAL DISK DIAGS ERROR - General Drive Error - Check Drive, Adapter
9124 - Check Cable
9125 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Drive, Adapter
9125 - Check Cable
9126 OPTICAL DISK DIAGS ERROR - Invalid Command - Check Drive, Adapter, Cable
9127 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Drive, Adapter
9127 - Check Cable
9128 OPTICAL DISK DIAGS ERROR - Disk Not Initialized - Check Drive, Adapter
9128 - Check Cable
9129 OPTICAL DISK DIAGS ERROR - Disk ID Did Not Match - Check Drive, Adapter
9129 - Check Cable
9130 OPTICAL DISK DIAGS ERROR - Read-Only Disk Installed - Check Disk
9130 - Check Drive, Adapter
9130 - Check Cable
9131 OPTICAL DISK DIAGS ERROR - No Disk Present - Check Disk
9131 - Check Drive, Adapter, Cable
9132 OPTICAL DISK DIAGS ERROR - Illegal Disk Detected - Check Disk
9132 - Check Adapter, Drive
9132 - Check Cable
9133 OPTICAL DISK DIAGS ERROR - No Disk Change Detected - Check Drive, Adapter
9133 - Check Cable
9134 OPTICAL DISK DIAGS ERROR - Read-Only Disk Detected - Check Drive, Adapter
9134 - Check Cable
9135 OPTICAL DISK DIAGS ERROR - Illegal Disk Detected - Check Drive, Adapter
9135 - Check Cable
9136 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Adapter, Drive
9136 - Check Cable
9138 OPTICAL DISK DIAGS ERROR - No Disk Change Detected - Retry test again
9138 - Check Drive, Adapter
9138 - Check Cable
9141 OPTICAL DISK DIAGS ERROR - No Disk Change Detected - Retry tests
9141 - Check Drive, Adapter
9141 - Check Cable
9144 OPTICAL DISK DIAGS ERROR - WRITE-PROTECT Window Not Opened - Retry tests
9144 - Check Drive
9144 - Check Adapter
9144 - Check Cable
9145 OPTICAL DISK DIAGS ERROR - No Disk Change Detected - Retry tests
9145 - Check Drive, Adapter
9145 - Check Cable
9146 OPTICAL DISK DIAGS ERROR - WRITE-PROTECT Window Not Closed - Retry tests
9146 - Check Drive
9146 - Check Adapter
9146 - Check Cable
9148 OPTICAL DISK DIAGS ERROR - Adapter Card - Check Adapter, Drive, or Cable
9150 OPTICAL DISK DIAGS ERROR - Seek Command Failed - Check Drive, Adapter
9150 - Check Cable
9151 OPTICAL DISK DIAGS ERROR - Not At Track Zero - Check Drive, Adapter
9151 - Check Cable
9152 OPTICAL DISK DIAGS ERROR - Track Address Error - Check Drive, Adapter
9152 - Check Cable
9153 OPTICAL DISK DIAGS ERROR - Not At Track 17099 - Check Drive, Adapter
9153 - Check Cable
9154 OPTICAL DISK DIAGS ERROR - Track Address Error - Check Drive, Adapter
9154 - Check Cable
9155 OPTICAL DISK DIAGS ERROR - Track Address 17K Not Found - Check Drive
9155 - Check Adapter
9155 - Check Cable
9156 OPTICAL DISK DIAGS ERROR - Seek Time Too Long - Check Drive, Adapter
9156 - Check Cable
9157 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Drive, Adapter
9157 - Check Cable
9158 OPTICAL DISK DIAGS ERROR - No Data Read Error Found - Check Drive, Adapter
9158 - Check Cable
9159 OPTICAL DISK DIAGS ERROR - No Null Sector Found - Check Drive, Adapter
9159 - Check Cable
9160 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Drive, Adapter
9160 - Check Cable
9161 OPTICAL DISK DIAGS ERROR - Write Command Failed - Check Drive, Adapter
9161 - Check Cable
9162 OPTICAL DISK DIAGS ERROR - Data Compare Error - Check Drive, Adapter
9162 - Check Cable
9163 OPTICAL DISK DIAGS ERROR - Read Verify Error - Check Drive, Adapter
9163 - Check Cable
9164 OPTICAL DISK DIAGS ERROR - Demark Verify Failed - Check Drive, Adapter
9164 - Check Cable
9165 OPTICAL DISK DIAGS ERROR - Demark Bit Not Set - Check Drive, Adapter
9165 - Check Cable
9166 OPTICAL DISK DIAGS ERROR - Seek 1/3 Timing Error - Check Drive, Adapter
9166 - Check Cable
9167 OPTICAL DISK DIAGS ERROR - Seek 2/3 Timing Error - Check Drive, Adapter
9167 - Check Cable
9168 OPTICAL DISK DIAGS ERROR - Seek 3/3 Timing Error - Check Drive, Adapter
9168 - Check Cable
9170 OPTICAL DISK DIAGS ERROR - Seek Error Set - Check Drive, Adapter, Cable
9171 OPTICAL DISK DIAGS ERROR - Controller RAM/ROM Error - Check Drive, Adapter
9171 - Check Cable
9172 OPTICAL DISK DIAGS ERROR - Demark Function Error - Check Drive, Adapter
9172 - Check Cable
9173 OPTICAL DISK DIAGS ERROR - Detected Error Set - Check Drive, Adapter
9173 - Check Cable
9174 OPTICAL DISK DIAGS ERROR - Modulator/Demodulator Error - Check Drive
9174 - Check Adapter
9174 - Check Cable
9175 OPTICAL DISK DIAGS ERROR - Invalid Command - Check Adapter, Drive, Cable
9176 OPTICAL DISK DIAGS ERROR - Illegal Disk Error - Check Adapter, Drive, Cable
9177 OPTICAL DISK DIAGS ERROR - Both drives set to same address or wrong address
9178 OPTICAL DISK DIAGS ERROR - ID Mismatch - Check Drive, Adapter, or Cable
9179 OPTICAL DISK DIAGS ERROR - Sector Not Found - Check Drive, Adapter, Cable
9181 OPTICAL DISK DIAGS ERROR - Sense Command Failed - Check Drive, Adapter
9181 - Check Cable
9182 OPTICAL DISK DIAGS ERROR - Read Command Error - Check Drive, Adapter, Cable
9185 OPTICAL DISK DIAGS ERROR - Diagnostic Track Error - Check Drive, Adapter
9185 - Check Cable
9186 OPTICAL DISK DIAGS ERROR - Diagnostic Demark Error - Check Drive, Adapter
9186 - Check Cable
9187 OPTICAL DISK DIAGS ERROR - No Demark Bit Set - Check Drive, Adapter, Cable
9198 OPTICAL DISK DIAGS ERROR - Invalid Command - Re-IPL CPU with ON/OFF switch